The Throttle sensor has a measuring range of 45°.
Dual redundancy Penny & Giles SRH302 Sensor
Electrical
- Measurement range: 20-360° in 1° increment
- Supply voltage: 5Vdc +-0.5Vdc and 9-30Vdc - auto selects
- Supply current: <17.5mA per output channel
- Supply reverse polarity protection: Yes
- Short-circuit protection to GND: Yes
- Short-circuit protection to supply: Only with 5Vdc regulated supply
- Over-voltage protection: Up to 40Vdc
- Power-on settlement: >1s
- Resolution: 12-bit (0.025° of measurement range)
- Linearity (absolute): +-0.4%
- Temperature coefficient: <30ppm/°C in 5Vdc mode, <110ppm/°C in 9-30Vdc mode
Voltage Outputs
- 0.5-4.5V output option (5V supply): 10-90% +-1% of Vsupply over measurement range
- 0.5-4.5V output option (9-30V supply): 0.5-4.5V +-3% absolute
- Monotonic range (0.5-4.5V output option): 5%/0.25V to 95%/4.75V nominal
- 0.2-4.8V output option (5V supply): 4-96% +-1% of Vsupply over measurement range
- 0.2-4.8V output option (9-30V supply): 0.2-4.8V +-3% absolute
- Monotonic range (0.2-4.8V output option): 2%/0.1V to 98%/4.9V nominal
- Load resistance: 10kOHM min. (resistive to GND)
- Output noise: <1mV rms
- Input.output delay: <2ms
Mechanical
- Mechanical Angle: 360° continuos
- Operating speed, MAX: 3600°/S
- Torque: 120 gm cm Max
- Weight: <70g
- Mounting: 2x holes to suit M4 screws tightened to 2.9Nm
- Cable: 18AWG 1.65mm OD
Environmental
- Operating temperature:
- -40°C to 140°C (-40°C to 120°C if conduit fitted)
- -40°C to 15.7°C at 9V (de-rate by 1.7°C for each 1V increase)
- Storage temperature: -40°C to 140°C (-40°C to 120°C if conduit fitted)
- Sealing: IP69k (excluding connector)if conduit fitted
- Vibration: BS EN 60068-2-64: 1995 Sec 8.4 (31.4g rms) 20 to 2000Hz
- Shock: Survival to 2500g all axes
- FE: 20 million operations
- MTTFd: >300 years
- Electromagnetic interference: EN 61000-4-6 to 100V/m 80-1000MHz & 1.4-2.7GHz
Electrical Connections
4-core cable, 18AWG
Red: V+1
Black: GND 1
Yellow: Output 1
Blue: V+ 2
Green: GND 2
White: Output 2
-
Brand:
AP Racing